About Silicon Primary Function: Sistema sa Pagdosis sa Infusion
Ang Silicon usa ka semi-automatic nga sistema sa pagdosis sa infusion nga nagkontrol sa gikusgon sa dagayday ug sa gidugayon sa intravenous nga tambal. Usa ka mekanikal nga timer ug usa ka flow rate valve ang gibutang sa ibabaw ug ubos sa infusion tube, aron ang mga medikal nga kawani makahimo sa pagbutang sa gikinahanglan nga drip rate ug oras nga walay mental nga pagkalkula. Kung mahuman na ang dosis, ang valve mobalhin ngadto sa physiological saline mode ug magpadayon ang pag-injeksyon, nga makapakunhod sa risgo sa mga sayop panahon sa busy nga mga panahon. Ang Silicon dili magkinahanglan og kuryente ug busa makaserbisyo sa mga dapit nga adunay limitado nga mga medikal nga kahinguhaan.
About the A' Design Award nga Pilak
Silicon Primary Function: Sistema sa Pagdosis sa Infusion usa ka mananaog sa A' Design Award nga Pilak, usa ka talagsaon kaayo nga prestihiyoso nga pag-ila nga gihatag sa labing taas nga lebel, matahom, ug makadani nga mga disenyo. Ang mga mananaog sa Pilak labihan ka hayag ug mamugnaon nga mga buhat nga nagpakita sa bantogan nga kahanas, talento, ug kamatngon sa ilang mga tigdesinyo. Gilauman nga ang Silicon Primary Function: Sistema sa Pagdosis sa Infusion mahimong talagsaon nga buhat nga ipasigarbo, dako ang pagkapropesyonal ug lawom ang kabag-ohan. Kini nga disenyo nga nakadaog og A' Design Award nga Pilak usa ka labihan ka mamatikdan, gihangaan nga imbento nga mapuslanon ug nagpalapad sa mga utlanan sa arte, siyensya, disenyo, ug teknolohiya. Silicon Primary Function: Sistema sa Pagdosis sa Infusion usa ka paglalang nga giinggit sa daghan, nga nagpukaw og mga tinguha, nagdala og positibo nga mga pagbati, ug nagsiga sa katingala ug paghangyo.
Press Kit
- Unique Properties
- Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
- Dimensions & Packaging
- Width 110mm x Depth 57mm x Height 302mm
- Tags
- Infusion,Dosing,Automatic,Timing,Control
- Production Technology
- After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
- Design Challenge
- This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
- Research
- In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
- Inspiration
- Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution. - Project Duration
- Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
- Operation Flow
- I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing. - Image Credits
- All Images:Designer Sheng-Lun Huang and Chih-Yen Lin