ETFE Membrane Facade Dobbeltskalsfacade by Petr Franta is a highly esteemed winner of the very prestigious 2022 A' Design Award i Bronze in Arkitektur-, Bygnings- og Konstruktionsdesign Competition Category.
BronzeArkitektur· 2022
ETFE Membrane Facade Dobbeltskalsfacade
by Petr Franta
Client: Ctu
A' Design Award i Bronze Winner in Arkitektur Category
Verified Award Winner
Verify Award Status for #134989The Design
About ETFE Membrane Facade Dobbeltskalsfacade
ETFE-membranfacade er en dobbeltskalsfacade designet til en forsknings- og undervisningsbygning. Det ydre skind er dannet af svejsede transparente puder af ethylen-tetrafluorethylen, tre meter brede og op til toogtreds meter lange, som holdes under konstant lufttryk og monteres diagonalt på en sekundær stålkonstruktion med aluminiumsklemmer. Facadehulrummet fungerer som en solfanger, og varm luft trækkes ind i ventilationsenhederne, hvilket reducerer energiforbruget med op til 30 procent. Membranen renses af regnvand og giver desuden akustisk beskyttelse mod trafikstøj fra gaden.
The Recognition
About the A' Design Award i Bronze
ETFE Membrane Facade Dobbeltskalsfacade er vinder af A' Design Award i Bronze, en højt prestigefyldt anerkendelse, der tildeles enestående designs, som udmærker sig ved kreativitet, opfindsomhed og skarpsindighed. Bronzevinderne er rigeligt dygtige og påfaldende kreative artefakter, der bekræfter deres designeres store erfaring, fantasi og snilde. ETFE Membrane Facade Dobbeltskalsfacade forventes at være en højt estimeret, beundret og kær genstand, der er bemærkelsesværdigt professionel og innovativ. Dette design, der har vundet A' Design Award i Bronze, indarbejder bedste praksis inden for kunst, videnskab, design og teknologi og er fremragende på grund af sin sans for detaljer. ETFE Membrane Facade Dobbeltskalsfacade tilfredsstiller pragtfuldt behov, rører længsler, charmerer følelser og appellerer til nysgerrigheden.
Behind the Design
Press Kit
Credits, team members and technical details provided by the designer.
- Unique Properties
- Applying Double Skin Facade with ETFE Ethylen Tetrafluor Ethylen transparent membrane assembly for energy saving up to 30 percent. Acting as solar collector with recuperation of hot air on the top floors in winter season.
Additional acoustic protection on busy traffic streetscape.
Aesthetics, added value as large span between structural members.
Self cleaning exterior of the facade ETFE membrane with additive chemical component rejecting dirt as automatic cleaning of the facade with rain water. - Dimensions & Packaging
- Pneumatic ETFE membrane cushions are 3 m wide and up to 62 m long, installed diagonally and kept under constant air pressure 300 Pa.
Cushions are anchored on secondary structural steel system with aluminium extrusion clamps structurally designed for wind load.
Acoustical properties in combination with triple glazing system 47 dB adds 10 dB to 57 dB in composite calculation.
Area of ETFE membrane facade is divided in two parts 1294 m2 and 570 m2.
Height of facade 20 m. Length of facade is 68 and 30 m. - Tags
- ETFE, Ethylen TetraFluor Ethylen membrane, Double skin pneumatic facade,
- Production Technology
- 3 m wide ETFE Ethylen Tetrafluor Ethylen cushions in south and west facade with seam in aluminium profiles on the secondary steel structure are welded cushions and kept under constant air pressure 300 Pa.
Weight is 1% of glass installation of outer skin.
Recuperation of hot air from facade as solar collector, energy saving up to 30%.
Self cleaning exterior ETFE membrane with additive chemical component rejecting dirt cleaning of the facade with rain water.
ETFE 50-years lifespan of the material. - Design Challenge
- Turning of the corner of diagonally placed pneumatic cushion of ETFE membrane detail in double skin facade.
Special aluminium extrusion detail was developed (with live size models) especially for this project to allow the twisting diagonal clamp with 1000 mm radius, placed on secondary steel tubing. We had to comply with European standards DIN different for aluminium and steel. Large mock-ups, samples and models were part of the design process to make sure that the membrane does not wrinkle. - Research
- Design research was very complex with scientists, structure engineers in applications ETFE membrane around the world (London, Munich, New York) - design datas with manufacturers, designers.
We searched design and structural properties of Ethylen TetraFluor Ethylen transparent membrane facades for building types use, duration in life span, wind load on pneumatic cushions, aluminium clamps detailing, secondary steel structure detailing, transparency properties, weight, width versus span dimensions. - Inspiration
- Presentation of 8 x 6 m sample of ETFE membrane cushion with pneumatic equipment for Allianz Arena in Munich by Herzog De Meuron Architects. It was used for football stadium, in England for museum in Leicester by Nicolas Grimshaw and other non transparent use. After researching those study cases around the world, later came to me the idea to use transparent double skin membrane for office type building for scientists, using transparent film membrane in double skin facade instead of glass.
- Project Duration
- Project design started in 2008 in Prague with presentation to Technical university scientists committee.
Realized in years from 2015 to 2017 on Czech Technical University in Prague campus for Czech Institute of Informatics, Robotics and Cybernetics of the CTU in Prague. - Operation Flow
- Applying double skin facade with ETFE membrane assembly for energy saving with recuperation of hot air on the top floors, saves 30 percent of an energy consumption.
From double facade acting as solar collector hot outside air is sucked into the ventilation HVAC units on each floor from two places - from south facade for the winter and transition period and from the north facade in the summer. (Solar collector - double facade between the glass facade and the outer facade of the ETFE facing south). - Patents
- Design of pneumatic cushions fasade with ETFE Ethylen TetraFluor Ethylen trademark Taiyo Europe.
- Team Members
- Architect: Petr Franta
Architect: Stepan Sekera
Architect: Petr Sobotka - Image Credits
- Image #1 Photographer Jiří Ryzsavy
Image #2 Photographer Jiří Ryzsavy
Image #3 Photographer Jiří Ryzsavy
Image #4 Photographer Jiří Ryzsavy