Silicon Infuza Dozila Sistemo by Sheng-Lun Huang and Chih-Yen Lin is a highly esteemed winner of the very prestigious 2021 Arĝenta A' Design Award in Idea kaj Koncepta Dezajno Competition Category.
ArĝentoIdeo· 2021
Silicon Infuza Dozila Sistemo
by Sheng-Lun Huang and Chih-Yen Lin
Client: Design Lions
Arĝenta A' Design Award Winner in Ideo Category
- 83,926
- Verified Award Winner
- Verify Award Status for #121915
The Design
About Silicon Infuza Dozila Sistemo
Silicon estas duonaŭtomata infuza dozila sistemo kiu regas la fluokvanton kaj la daŭron de intravejna medikamento. Meĥanika horloĝo kaj fluokvanta valvo estas lokitaj super kaj sub la infuza tubo, tiel medicina personaro povas agordi la bezonatan gutrapidecon kaj tempon sen mensa kalkulado. Kiam la dozo kompletiĝas, la valvo ŝanĝiĝas al fiziologia salakva reĝimo kaj la injektado daŭras, kio reduktas la riskon de eraroj dum okupataj periodoj. Silicon bezonas neniom da elektro kaj povas do servi areojn kun limigitaj medicinaj rimedoj.
The Recognition
About the Arĝenta A' Design Award
Silicon Infuza Dozila Sistemo estas gajninto de la Arĝenta A' Design Award, grandege prestiĝa rekono donata al plejklasaj, belegaj kaj impresaj dezajnoj. La Arĝentaj gajnintoj estas treege brilaj kaj treege kreemaj verkoj, kiuj ilustras la elstaran sperton, talenton kaj sagacon de siaj dezajnistoj. Oni atendas, ke Silicon Infuza Dozila Sistemo estu mirinda, montrinda verko, kiu estas rimarkinde profesia kaj profunde nova. Ĉi tiu dezajno gajninta la Arĝentan A' Design Award estas tre rimarkinda, admirata inventaĵo, kiu profitigas kaj antaŭenigas la limojn de arto, scienco, dezajno kaj teknologio. Silicon Infuza Dozila Sistemo estas vaste enviata kreaĵo, kiu vekas dezirojn, alportas pozitivajn sentojn kaj ekbrilas miron kaj mirigon.
Behind the Design
Press Kit
Credits, team members and technical details provided by the designer.
- Unique Properties
- Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
- Dimensions & Packaging
- Width 110mm x Depth 57mm x Height 302mm
- Tags
- Infusion,Dosing,Automatic,Timing,Control
- Production Technology
- After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
- Design Challenge
- This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
- Research
- In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
- Inspiration
- Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution. - Project Duration
- Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
- Operation Flow
- I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing. - Team Members
- Designer:Sheng-Lun Huang
Designer:Chih-Yen Lin
Professor:Kai-Chu Li
Medical team:Ciao-Yi Chen
Medical team:Ya-Ling Chen
Medical team:He-Yen Lin - Image Credits
- All Images:Designer Sheng-Lun Huang and Chih-Yen Lin
Sponsored
Explore Beyond Designers.org
Discover products, services and opportunities from our advertising partners.
More to Explore
Related Designs
Explore more award-winning designs from the same category, selected by merit.