Bracesys Adaptebla Rigida Orteza Aparato

by Osteoid Design Team

  • Ora A' Design Award 2025 in Medicina Produkto
  • CLIENT: Osteoid Saglik Teknolojilari AS
  • Estimated Number of Design Views: 44,461
  • Verification code 406CD20E30 · Verify this award
Email this page

Colors

About Bracesys Adaptebla Rigida Orteza Aparato

Bracesys ofertas modulan ortopedian ortezilon kiu adaptiĝas al la pacienta korpo dum la tuta resaniĝa proceso. Desegnita por surloka alĝustigo kaj facila adapto, ĝi anstataŭigas tradician gipsaĵon per pli praktika, higiena kaj komforta alternativo. Ĝia reuzebla strukturo helpas redukti medicinan rubon, dum normigitaj grandoj igas ĝin pli alirebla por diversaj pacientgrupoj. Bracesys alportas flekseblecon, daŭripovecon kaj uzant-centritan pensadon al ortopedia flegado.

About the Ora A' Design Award

Bracesys Adaptebla Rigida Orteza Aparato estas gajninto de la Ora A' Design Award, treege prestiĝa rekono donata al unuaklasaj, mirindaj kaj elstaraj dezajnoj. La Oraj gajnintoj estas treege novigaj, viziecaj kaj glamure miregigaj kreaĵoj, kiuj reflektas la talenton, saĝon kaj lertecon de siaj dezajnistoj. Oni atendas, ke Bracesys Adaptebla Rigida Orteza Aparato estu tre laŭdata, tendencdifina kaj monumenta inventaĵo, kiu liveras senprecedencan valoron. Ĉi tiu dezajno gajninta la Oran A' Design Award estas spektakla, estimata projekto, kiu tre profitigas kaj antaŭenigas la limojn de arto, scienco, dezajno kaj teknologio. Bracesys Adaptebla Rigida Orteza Aparato kreas intensajn dezirsentojn, vekas pasion, kuraĝigas kreemon kaj fascinas nin.

Press Kit

Unique Properties
Bracesys is a patented, rigid orthopedic brace framework featuring segmented units connected by adjustable articulating connectors and tension dials. Clinicians independently fine-tune each segment, closely matching patient anatomy, providing secure immobilization, and accommodating anatomical changes during recovery. It simplifies clinical procedures, enhances daily patient comfort, and promotes sustainability through recyclable materials and reuse within controlled clinical protocols.
Dimensions & Packaging
Bracesys includes specific models like distal radius, colles, shaft fractures in four standardized sizes, covering anatomical variations from the 5th to 95th percentile. A mid-sized Colles fracture brace typically weighs 150 grams, measuring approximately 190 x 90 x 115 mm assembled, and folds flat into an A4 sized envelope for convenient transport. Clinicians use small, screwdriver-sized tools for rapid fitting, precise customization, and incremental adjustments during patient recovery.
Tags
Rigid Orthopedic Brace, Customizable Orthosis, Sustainable Healthcare, Modular Framework, 3D Orthotics, Medical Cast
Production Technology
Bracesys was developed within a CAD environment through iterative prototyping and 3D-printing SLS/MJF using medical-grade Nylon 12, reinforced by CNC-machined aluminum, stainless steel, and Kevlar cables for robust structural performance. Anatomical accuracy was ensured by analyzing hundreds of anonymized patient CT scans via AI-driven segmentation, implicit skinning algorithms, and statistical shape analysis to precisely define patient-contact surfaces and ensure anatomical compatibility.
Design Challenge
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside with running the business sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Research
This applied research addresses the need for anatomically accurate, rapidly customizable orthopedic braces. Over 600 anonymized patient hand CT scans were analyzed through AI driven segmentation ,Pix2Pix GAN, implicit skinning algorithms for standardized anatomic alignment, and statistical modeling, Principal Component Analysis, for sizing. Mechanical tests validated structural integrity, while clinical use provided feedback for sizing, comfort and fitting procedures influencing the design.
Inspiration
Current orthopedic solutions present trade-offs: off-the-shelf braces rarely fit accurately, while custom 3D-printed alternatives involve lengthy, complex processes that limit their clinical use. Inspired by the precision engineering of timepiece mechanics and sailing rigging systems, Bracesys emerged from a quest to develop a rapid, expert-driven approach that precisely accommodates diverse and evolving patient anatomies, prioritizing comfort, speed, and sustainability.
Project Duration
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside another demands sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Operation Flow
Bracesys is placed around the limb in a loosely connected circular form, with pre-configured structural segments linked by articulated connectors and loose internal cables, naturally conforming to clinically prescribed anatomical alignment. Clinicians use tools to adjust connector length and incrementally tighten integrated tension dials, mechanically locking the brace into a rigid, supportive configuration. Spring-loaded quick-release pins enable easy loosening for adjustments or brace removal.
Patents
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted patents / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending patent applicants / Applicant Osteoid Saglik Teknolojileri AS
Image Credits
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending / Patent applicant Osteoid Saglik Teknolojileri AS

Image #1 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #2 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #3 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #4 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.