Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan by Osteoid Design Team

Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan by Osteoid Design Team is a highly esteemed winner of the very prestigious 2025 A' Design Award Emas in Desain Perangkat Medis dan Peralatan Medis Competition Category.


EmasProduk Medis· 2025

Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan

by Osteoid Design Team

Client: Osteoid Saglik Teknolojilari AS

A' Design Award Emas Winner in Produk Medis Category

Colors

The Design

About Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan

Bracesys menawarkan penyangga ortopedi modular yang beradaptasi dengan tubuh pasien selama proses penyembuhan. Dirancang untuk pemasangan di tempat dan penyesuaian yang mudah, produk ini menggantikan gips tradisional dengan alternatif yang lebih praktis, higienis, dan nyaman. Strukturnya yang dapat digunakan kembali membantu mengurangi limbah medis, sementara ukuran terstandar membuatnya lebih mudah diakses oleh berbagai kelompok pasien. Bracesys menghadirkan fleksibilitas, keberlanjutan, dan pemikiran yang berpusat pada pengguna dalam perawatan ortopedi.

The Recognition

About the A' Design Award Emas

Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan adalah pemenang A' Design Award Emas, pengakuan yang sangat bergengsi yang diberikan kepada desain kelas satu, menakjubkan, dan menonjol. Pemenang Emas adalah kreasi yang sangat inovatif, visioner, dan berkilau memukau yang mencerminkan kejeniusan, kebijaksanaan, dan kepiawaian para desainernya. Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan diharapkan menjadi penemuan yang sangat dipuji, perintis tren, dan monumental yang memberikan nilai tanpa preseden. Desain pemenang A' Design Award Emas ini adalah proyek yang spektakuler dan disegani yang sangat bermanfaat bagi dan memajukan batas-batas seni, sains, desain, dan teknologi. Bracesys Penyangga Ortotik Rigid yang Dapat Disesuaikan menciptakan perasaan keinginan yang kuat, membangkitkan gairah, mendorong kreativitas, dan memukau kita.

Behind the Design

Press Kit

Credits, team members and technical details provided by the designer.

Unique Properties
Bracesys is a patented, rigid orthopedic brace framework featuring segmented units connected by adjustable articulating connectors and tension dials. Clinicians independently fine-tune each segment, closely matching patient anatomy, providing secure immobilization, and accommodating anatomical changes during recovery. It simplifies clinical procedures, enhances daily patient comfort, and promotes sustainability through recyclable materials and reuse within controlled clinical protocols.
Dimensions & Packaging
Bracesys includes specific models like distal radius, colles, shaft fractures in four standardized sizes, covering anatomical variations from the 5th to 95th percentile. A mid-sized Colles fracture brace typically weighs 150 grams, measuring approximately 190 x 90 x 115 mm assembled, and folds flat into an A4 sized envelope for convenient transport. Clinicians use small, screwdriver-sized tools for rapid fitting, precise customization, and incremental adjustments during patient recovery.
Tags
Rigid Orthopedic Brace, Customizable Orthosis, Sustainable Healthcare, Modular Framework, 3D Orthotics, Medical Cast
Production Technology
Bracesys was developed within a CAD environment through iterative prototyping and 3D-printing SLS/MJF using medical-grade Nylon 12, reinforced by CNC-machined aluminum, stainless steel, and Kevlar cables for robust structural performance. Anatomical accuracy was ensured by analyzing hundreds of anonymized patient CT scans via AI-driven segmentation, implicit skinning algorithms, and statistical shape analysis to precisely define patient-contact surfaces and ensure anatomical compatibility.
Design Challenge
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside with running the business sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Research
This applied research addresses the need for anatomically accurate, rapidly customizable orthopedic braces. Over 600 anonymized patient hand CT scans were analyzed through AI driven segmentation ,Pix2Pix GAN, implicit skinning algorithms for standardized anatomic alignment, and statistical modeling, Principal Component Analysis, for sizing. Mechanical tests validated structural integrity, while clinical use provided feedback for sizing, comfort and fitting procedures influencing the design.
Inspiration
Current orthopedic solutions present trade-offs: off-the-shelf braces rarely fit accurately, while custom 3D-printed alternatives involve lengthy, complex processes that limit their clinical use. Inspired by the precision engineering of timepiece mechanics and sailing rigging systems, Bracesys emerged from a quest to develop a rapid, expert-driven approach that precisely accommodates diverse and evolving patient anatomies, prioritizing comfort, speed, and sustainability.
Project Duration
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside another demands sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Operation Flow
Bracesys is placed around the limb in a loosely connected circular form, with pre-configured structural segments linked by articulated connectors and loose internal cables, naturally conforming to clinically prescribed anatomical alignment. Clinicians use tools to adjust connector length and incrementally tighten integrated tension dials, mechanically locking the brace into a rigid, supportive configuration. Spring-loaded quick-release pins enable easy loosening for adjustments or brace removal.
Patents
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted patents / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending patent applicants / Applicant Osteoid Saglik Teknolojileri AS
Team Members
Project lead: Deniz Karasahin
Software lead: Gokce Guven
Biomedical engineer: Feyza Aykut
Mechanical engineer: Aykan Duzkaya
Image Credits
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending / Patent applicant Osteoid Saglik Teknolojileri AS

Image #1 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #2 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #3 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #4 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #5 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Video #1 / Cameraman / Murat Sariaslan / Santral Fotoğraf, 2025.

Sponsored

Explore Beyond Designers.org

Discover products, services and opportunities from our advertising partners.

Good Design Deserves Great Recognition

The A' Design Award is an international, juried accolade for good design. Take part in the A' Design Award to get an opportunity to earn meritocratic recognition, gain fame, prestige and publicity for your work. Nominate your work for the A' Design Award and compete for the coveted A' Design Prize.

Nominate