Skip to content
Silicon Primärfunktioun: Infusiouns-Doséierungssystem by Sheng-Lun Huang and Chih-Yen Lin

Silicon Primärfunktioun: Infusiouns-Doséierungssystem by Sheng-Lun Huang and Chih-Yen Lin is a highly esteemed winner of the very prestigious 2021 A' Design Award an Sëlwer in Iddi a Konzeptuellt Design Competition Category.


SëlwerIddi· 2021

Silicon Primärfunktioun: Infusiouns-Doséierungssystem

by Sheng-Lun Huang and Chih-Yen Lin

Client: Design Lions

A' Design Award an Sëlwer Winner in Iddi Category

Colors

The Design

About Silicon Primärfunktioun: Infusiouns-Doséierungssystem

Silicon ass en hallefautomatescht Infusiouns-Doséierungssystem, dat den Duerchflossrate an d'Dauer vun der intravenöser Medikatioun kontrolléiert. En mechaneschen Timer an e Ventil fir den Duerchflossrate ginn iwwer an ënner dem Infusiounsschlauch plazéiert, sou datt medezinescht Personal déi néideg Drëpsrate an d'Zäit ouni mentalt Rechnen astelle kann. Wann d'Dosis komplett ass, wiesselt de Ventil an e physiologesche Kachsalz-Modus an d'Injektioun geet weider, wat de Risiko vu Feeler wärend belaaschtenden Perioden reduzéiert. Silicon brauch keen Stroum a ka dofir Regiounen mat limitéierte medezinesche Ressourcë bedéngen.

The Recognition

About the A' Design Award an Sëlwer

Silicon Primärfunktioun: Infusiouns-Doséierungssystem ass e Gewënner vum A' Design Award an Sëlwer, enger aussergewéinlech prestigiéiser Unerkennung, déi un Designe vun der héchster Qualitéit, prächteg a beandrockend vergi gëtt. Sëlwer-Gewënner si bemierkenswäert brillant a ganz kreativ Wierker, déi d'erausragend Expertise, d'Talent an d'Schaarfsënnegkeet vun hire Designer weisen. Et gëtt erwaart, datt Silicon Primärfunktioun: Infusiouns-Doséierungssystem e wonnerbart, mustergëlteg, bemierkenswäert professionellt an déif innovatiivt Wierk ass. Dëst mam Sëlwer ausgezeechent Design ass eng bemierkenswäert, bewonnert Erfindung, déi dozou bäidréit, d'Grenze vun der Konscht, der Wëssenschaft, vum Design an der Technologie ze erweideren. Silicon Primärfunktioun: Infusiouns-Doséierungssystem ass eng Kreatioun, op déi vill neidesch sinn, déi Wënsch erweckt, positiv Gefiller bréngt an Erstaunen a Wonner erweckt.

Behind the Design

Press Kit

Credits, team members and technical details provided by the designer.

Unique Properties
Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
Dimensions & Packaging
Width 110mm x Depth 57mm x Height 302mm
Tags
Infusion,Dosing,Automatic,Timing,Control
Production Technology
After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
Design Challenge
This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
Research
In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
Inspiration
Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution.
Project Duration
Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
Operation Flow
I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing.
Team Members
Designer:Sheng-Lun Huang
Designer:Chih-Yen Lin
Professor:Kai-Chu Li
Medical team:Ciao-Yi Chen
Medical team:Ya-Ling Chen
Medical team:He-Yen Lin
Image Credits
All Images:Designer Sheng-Lun Huang and Chih-Yen Lin

Sponsored

Explore Beyond Designers.org

Discover products, services and opportunities from our advertising partners.

Good Design Deserves Great Recognition

Nominate Your Work for the A' Design Award.

Nominate