Emas Produk Perubatan · 2026
Vivos Sistem Pembedahan Oftalmik
by Olcayto Guelec and David Geuder
- A' Design Award Emas 2026 in Produk Perubatan
- CLIENT: Geuder AG
- Estimated Number of Design Views: 53,358
- Verification code 7DEB548122 · Verify this award
Colors
About Vivos Sistem Pembedahan Oftalmik
Vivos mentakrif semula stesen kerja pembedahan sebagai platform yang berkembang seiring dengan aspirasi klinikal. Tiga konfigurasi, iaitu Core, Nova, dan Nova+, memperluas keupayaan tanpa penggantian sistem, satu-satunya seni bina naik taraf seumpamanya dalam pembedahan oftalmik. Antara muka tunggal, yang disahkan pada kepuasan penggunaan kali pertama sebanyak 91.7 peratus tanpa latihan terlebih dahulu, mencerminkan reka bentuk yang dibina berpaksikan pakar bedah dan bukannya prosedur. Sambungan instrumen bercahaya, bahan yang halus dan perincian yang terkawal memberikan peranti ini kehadiran yang tenang dan yakin, bebas daripada kekusutan visual yang lazim dalam kategori ini.
About the A' Design Award Emas
Vivos Sistem Pembedahan Oftalmik ialah pemenang A' Design Award Emas, pengiktirafan yang amat berprestij yang dianugerahkan kepada reka bentuk kelas pertama, menakjubkan dan cemerlang. Pemenang Emas ialah ciptaan yang sangat inovatif, berwawasan dan berkilau memukau yang mencerminkan kegeniusan, kebijaksanaan dan kepakaran pereka bentuknya. Vivos Sistem Pembedahan Oftalmik diharapkan menjadi ciptaan yang sangat dipuji, perintis aliran dan monumental yang memberikan nilai tanpa tandingan. Reka bentuk pemenang A' Design Award Emas ini ialah projek yang menakjubkan dan disegani yang memberi manfaat besar kepada dan memajukan batas seni, sains, reka bentuk dan teknologi. Vivos Sistem Pembedahan Oftalmik mencetuskan perasaan keinginan yang kuat, membangkitkan semangat, menggalakkan kreativiti dan memukau kita.
Press Kit
- Unique Properties
- Vivos is the only ophthalmic surgery system that grows with clinical needs. Core for cataract. Nova adds vitrectomy. Plus adds laser. One platform. One interface. One training investment. Independent usability validation confirmed 92 percent user satisfaction among first time users. Illuminated connection sockets were rated positively by all study participants. Premium materials and restrained detailing give the device a likeable presence without the visual noise typical of the category.
- Dimensions & Packaging
- Display: 24 inch capacitive touchscreen. Vitrectomy: up to 40000 cuts per min. Vacuum: up to 700 mmHg, highest in category. Phacoemulsification: 53 kHz piezoelectric. IOP: active real-time (VIVOS Balance). Endolaser: 532 nm. Illumination: SOLEA LED, 16.9M colours, 2 ports, Retina Protection Mode. CE pending, submitted Feb 2026. ISO 13485 2016.
- Tags
- Ophthalmic Surgery System, Medical Device Design, Phacoemulsification, Vitrectomy, Modular Medical Platform, Surgical Ergonomics, Workflow Design, German Medical Engineering, Usability Validation, Premium Medical Aesthetics
- Production Technology
- Medical-grade polycarbonate housing, antimicrobial surface coating rated for over 10,000 disinfection cycles. Piezoelectric phacoemulsification at 53 kHz with beveled-up probe geometry for optimised fluidics. Pneumatic vitrectomy probe up to 40,000 cuts/min. IEC 60601-1 compliant. Modular quick-change cassette - single or multi-patient - tool-free exchange. Compatible with older phaco handpieces, protecting prior investment. Individually assembled in Heidelberg. ISO 13485:2016, IEC 62366-1, IEC 60601-1, CE pending
- Design Challenge
- The central challenge was integrating six surgical functions, historically distributed across two to three separate devices, into a single platform without increasing cognitive load. Internally, decades of segmented product architecture and a 75-year heritage required rethinking established engineering logic. Externally, MDR regulations, IEC 62366 1 usability standards and strict OR hygiene constraints limited design freedom. Maintaining identical UX across Core, Nova and Plus while ensuring durability for thousands of cleaning cycles demanded systemic redesign rather than incremental improvement.
- Research
- Usability research was conducted. Objective: reduce cognitive load without limiting clinical capability. Methodology: iterative co-design workshops with surgeons, Geuder teams and engineering, followed by independent summative validation per IEC 62366-1. Data collection included usability testing and task-based evaluations. Participants: 13 first-time users at RWTH Aachen University, 2026. Results: 91.7% satisfaction, no unacceptable residual risks. Insights validated the workflow UI, surgeon profiles and illuminated sockets, contributing to greater efficiency, improved patient safety and long-term system adoption in clinical practice.
- Inspiration
- Ophthalmic surgery is precise. Why should its devices remain fragmented, complex and visually uninspiring. Anterior and posterior procedures require separate investments, training and ecosystems not because clinical need requires it but because no manufacturer redesigned the architecture around the surgeon. Geuder AG with seventy five years of ophthalmic expertise asked what if one platform could grow without hardware replacement. Validated by independent study and unique in its modular upgrade logic.
- Project Duration
- The project was developed in Heidelberg, Germany by Geuder AG. Development spanned multiple months with iterative design and engineering phases conducted in close collaboration with ophthalmic surgeons and operating room nursing staff. Summative usability validation was performed at RWTH Aachen University in early 2026. CE Mark application was submitted on 27 February 2026. Public market launch is scheduled for June 2026.
- Operation Flow
- Before each procedure, the surgeon selects a personal profile, preloading preferred settings and pedal sensitivity. A three-column touchscreen maps each surgical step as a visual sequence. Colour-coded modules allow instant identification in a darkened theatre. Illuminated sockets guide instrument connection by touch. The foot pedal, with individually adjustable actuation force, controls fluid flow and laser hands-free. Eye pressure is monitored and adjusted in real time.
- Patents
- Design copyright: Geuder AG, 2026. Patent application pending. All rights reserved.
- Image Credits
- Photography Geuder AG, 2026