Argint Idee · 2021
Silicon Sistem de Dozare a Perfuziei
by Sheng-Lun Huang and Chih-Yen Lin
- A' Design Award de Argint 2021 in Idee
- CLIENT: Design Lions
- Estimated Number of Design Views: 83,926
- Verification code F0C588E17A · Verify this award
Colors
About Silicon Sistem de Dozare a Perfuziei
Silicon este un sistem semiautomat de dozare a perfuziei care controlează debitul și durata administrării medicației intravenoase. Un temporizator mecanic și o valvă de reglare a debitului sunt amplasate deasupra și dedesubtul tubului de perfuzie, astfel încât personalul medical să poată seta ritmul de picurare și timpul necesar fără calcule mentale. La finalizarea dozei, valva comută în modul de ser fiziologic, iar injectarea continuă, ceea ce reduce riscul de erori în perioadele aglomerate. Silicon nu necesită electricitate și poate deservi, prin urmare, zonele cu resurse medicale limitate.
About the A' Design Award de Argint
Silicon Sistem de Dozare a Perfuziei a câștigat A' Design Award de Argint, o recunoaștere extraordinar de prestigioasă acordată designurilor de top, superbe și impresionante. Câștigătorii Argintului sunt lucrări extraordinar de strălucite și extrem de creative, care ilustrează expertiza, talentul și perspicacitatea remarcabile ale designerilor lor. Se așteaptă ca Silicon Sistem de Dozare a Perfuziei să fie o lucrare minunată, de referință, remarcabil de profesionistă și profund inovatoare. Acest design câștigător al A' Design Award de Argint este o invenție foarte notabilă și admirată, care aduce beneficii și împinge limitele artei, științei, designului și tehnologiei. Silicon Sistem de Dozare a Perfuziei este o creație extrem de invidiată, care trezește dorințe, aduce sentimente pozitive și stârnește uimire și mirare.
Press Kit
- Unique Properties
- Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
- Dimensions & Packaging
- Width 110mm x Depth 57mm x Height 302mm
- Tags
- Infusion,Dosing,Automatic,Timing,Control
- Production Technology
- After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
- Design Challenge
- This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
- Research
- In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
- Inspiration
- Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution. - Project Duration
- Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
- Operation Flow
- I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing. - Image Credits
- All Images:Designer Sheng-Lun Huang and Chih-Yen Lin