Songpingshan este o stație de pompieri din Shenzhen, China. Stația de gradul I are o suprafață de teren de 3.660,1 metri pătrați și o suprafață construită totală de 5.791,64 metri pătrați, găzduind șapte autospeciale de pompieri. O dispunere cu curte interioară reduce zgomotul provenit de la bulevardul aflat pe latura nordică. Garajul pentru pompieri, holul de intrare, cantina și camera de comunicații sunt amplasate la parter. Camerele de pregătire pentru serviciu, camerele de operațiuni și încăperile auxiliare ocupă etajele superioare. Rutele vizitatorilor trec printr-un coridor de pe mezanin, astfel încât antrenamentele zilnice și rutele de serviciu nu sunt perturbate.

The Recognition

About the A' Design Award de Bronz

Songpingshan Stație de Pompieri a câștigat A' Design Award de Bronz, o recunoaștere extrem de prestigioasă acordată designurilor remarcabile care se disting prin creativitate, ingeniozitate și istețime. Câștigătorii Bronzului sunt artefacte din plin pricepute și izbitor de creative, care atestă experiența vastă, imaginația și resursele designerilor lor. Se așteaptă ca Songpingshan Stație de Pompieri să fie un obiect foarte apreciat, admirat și prețuit, remarcabil de profesionist și inovator. Acest design câștigător al A' Design Award de Bronz încorporează cele mai bune practici din artă, știință, design și tehnologie și este excelent prin atenția la detalii. Songpingshan Stație de Pompieri satisface splendid nevoile, atinge dorințele, vrăjește sentimentele și stârnește curiozitatea.

Behind the Design

Press Kit

Credits, team members and technical details provided by the designer.

Unique Properties
The main entrance and exit is set at the southeast corner of the site, through which firefighters and visitors enter the fire station. The fire garage faces the square. Fire garage, entrance hall, canteen and communication room are arranged on 1F, firefighters duty preparation room and lavatory are organized on 2F, and operation room and auxiliary room are set on 3F, 4F and 5F. Basement mainly accommodates equipment rooms. Multiple rest platforms are arranged to enrich the lives of firefighters.
Dimensions & Packaging
The project is a Grade-1 fire station with a plot area of 3,660.1 square meters and a gross floor area of 5,791.64 square meters, which can accommodate 7 fire trucks. Fire garage, entrance hall, canteen and communication room are arranged on 1F, firefighters duty preparation room and lavatory are organized on 2F, and operation room and auxiliary room are set on 3F, 4F and 5F.
Tags
Inner courtyard-style layout, Grade-1 fire station, Special set-back line, Overlapping circulation routes, Shading structure, Green design, Sponge city technologies
Production Technology
The forms of each building feature a simple style and the building bodies have reasonable coefficient. The window-to-wall ratio and the area of curtain wall and external window meet relevant regulations and requirements. Each building is designed based on facades and adopts shading structure.
Green architecture and sponge city technologies are applied to roof fruit garden. Concave green area is set for rainwater absorption, storage and seepage, controlling the rainwater runoff within the site.
Design Challenge
Limited land area: The building set-back lines cannot be fully in accordance with the requirements of Shenzhen local regulations. After several times of negotiations with the planning bureau about set-back lines, the design team reached a reasonable bargain: the plot is set back at least 1.0m on the east side, 2.3m on the south side, 38.1m on the west side, and at least 8.15m on the north side. In this way, the fire station and the sports field are reasonably arranged within the limited land.
Research
Due to the Songpingshan Gas Vaporizing Station on the northwest corner, the building should be set back for 50m according to relevant regulations, which has a great impact on the spatial layout. On the basis of satisfying the requirements of set-back line, the design creates a curved screen wall to unfold a "dialogue" with the gas vaporizing station.
In response to the serious noise interference from Beihuan Avenue on the north, the project adopts an inner courtyard-style layout.
Inspiration
The project is designed according to the research results of "2014 Shenzhen Fire Station Standardization Design Workshop". The experience of this project will be utilized to establish construction standards on fire stations in Shenzhen, so as to satisfy the requirements of building more fire stations and provide a reference for domestic fire station constructions.
Project Duration
The project started in September 2016 and finished in December 2019 at the intersection of Baoshen Road and Keyuan Road, Nanshan District in Shenzhen, China.
Operation Flow
Fire trucks leave the station via an exit nearby the street, greatly improving response efficiency.
Overlapping circulation routes: Public participation is encouraged. Visiting areas open for citizens are mainly organized on 1F and mezzanine. Visitors' circulation routes pass through the mezzanine corridor, without affecting the internal daily training and duty circulation routes of firefighters.
Team Members
Zhong Zhong
Zhong Botao
Ma Ying
Wei Qijing
Zhang Zilu
Wang Min
Yong Yong
Xiong Feng
Wu Zirong
He Xiaoming
Liu Mu
Tang Jin
Image Credits
Inter_mountain

Sponsored

Explore Beyond Designers.org

Discover products, services and opportunities from our advertising partners.

Good Design Deserves Great Recognition

Nominate Your Work for the A' Design Award.

Nominate