Skip to content
Silicon سلڪان انفيوزن ڊوزنگ سسٽم by Sheng-Lun Huang and Chih-Yen Lin

Silicon سلڪان انفيوزن ڊوزنگ سسٽم by Sheng-Lun Huang and Chih-Yen Lin is a highly esteemed winner of the very prestigious 2021 A' Design Award چاندي انعام in خيال ۽ تصوراتي ڊيزائن Competition Category.


چانديخيال· 2021

Silicon سلڪان انفيوزن ڊوزنگ سسٽم

by Sheng-Lun Huang and Chih-Yen Lin

Client: Design Lions

A' Design Award چاندي انعام Winner in خيال Category

Colors

The Design

About Silicon سلڪان انفيوزن ڊوزنگ سسٽم

سلڪان هڪ نيم خودڪار انفيوزن ڊوزنگ سسٽم آهي جيڪو رگ ذريعي ڏنل دوا جي وهڪري جي رفتار ۽ مدت کي ڪنٽرول ڪري ٿو. هڪ ميڪانيڪي ٽائيمر ۽ هڪ فلو ريٽ والو انفيوزن ٽيوب جي مٿان ۽ هيٺان رکيا وڃن ٿا، انهيءَ ڪري طبي عملو ذهني حساب ڪتاب کان سواءِ گهربل ڊرپ ريٽ ۽ وقت مقرر ڪري سگهي ٿو. جڏهن خوراڪ مڪمل ٿي وڃي ٿي، تڏهن والو فزيولاجيڪل ساليائن موڊ ۾ تبديل ٿي وڃي ٿو ۽ انجيڪشن جاري رهي ٿو، جيڪو مصروف وقتن دوران غلطين جي خطري کي گهٽائي ٿو. سلڪان کي بجلي جي ضرورت نه آهي ۽ انهيءَ ڪري اهو محدود طبي وسيلن وارن علائقن کي خدمت مهيا ڪري سگهي ٿو.

The Recognition

About the A' Design Award چاندي انعام

Silicon سلڪان انفيوزن ڊوزنگ سسٽم A' Design Award چاندي انعام جو کٽيندڙ آهي، غير معمولي حد تائين معزز اعتراف جيڪو اعليٰ ترين درجي جي، شاندار ۽ متاثر ڪندڙ ڊيزائنن کي ڏنو وڃي ٿو. چاندي جا کٽيندڙ تمام گهڻا روشن ۽ انتهائي تخليقي ڪم آهن، جيڪي پنهنجي ڊيزائنرن جي شاندار مهارت، صلاحيت ۽ ذڪاوت کي ظاهر ڪن ٿا. Silicon سلڪان انفيوزن ڊوزنگ سسٽم کان اميد ڪئي وڃي ٿي ته اهو هڪ شاندار نمائشي ڪم هوندو، قابل ذڪر حد تائين پيشه ورانه ۽ ڳوڙهي جدت وارو. هي ڊيزائن جنهن A' Design Award چاندي انعام کٽيو آهي، هڪ انتهائي قابل ذڪر، ساراهيل ايجاد آهي جيڪا فائدو ڏئي ٿي ۽ فن، سائنس، ڊيزائن ۽ ٽيڪنالاجي جون حدون وڌائي ٿي. Silicon سلڪان انفيوزن ڊوزنگ سسٽم هڪ اهڙي تخليق آهي جنهن تي گهڻا حسد ڪن ٿا، جيڪا خواهشون جاڳائي ٿي، مثبت جذبا آڻي ٿي ۽ حيرت ۽ تعجب جي چڻنگ ٻاري ٿي.

Behind the Design

Press Kit

Credits, team members and technical details provided by the designer.

Unique Properties
Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
Dimensions & Packaging
Width 110mm x Depth 57mm x Height 302mm
Tags
Infusion,Dosing,Automatic,Timing,Control
Production Technology
After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
Design Challenge
This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
Research
In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
Inspiration
Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution.
Project Duration
Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
Operation Flow
I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing.
Team Members
Designer:Sheng-Lun Huang
Designer:Chih-Yen Lin
Professor:Kai-Chu Li
Medical team:Ciao-Yi Chen
Medical team:Ya-Ling Chen
Medical team:He-Yen Lin
Image Credits
All Images:Designer Sheng-Lun Huang and Chih-Yen Lin

Sponsored

Explore Beyond Designers.org

Discover products, services and opportunities from our advertising partners.

Good Design Deserves Great Recognition

Nominate Your Work for the A' Design Award.

Nominate