Skip to content
Silicon Primary Function: انفیوژن ڈوزنگ سسٹم by Sheng-Lun Huang and Chih-Yen Lin

Silicon Primary Function: انفیوژن ڈوزنگ سسٹم by Sheng-Lun Huang and Chih-Yen Lin is a highly esteemed winner of the very prestigious 2021 A' Design Award چاندی دا انعام in خیال تے تصوراتی ڈیزائن Competition Category.


چاندیخیال· 2021

Silicon Primary Function: انفیوژن ڈوزنگ سسٹم

by Sheng-Lun Huang and Chih-Yen Lin

Client: Design Lions

A' Design Award چاندی دا انعام Winner in خیال Category

83,926

Verified Award Winner

Verify Award Status for #121915

Colors

The Design

About Silicon Primary Function: انفیوژن ڈوزنگ سسٹم

سلیکون ہک سیمی آٹومیٹک انفیوژن ڈوزنگ سسٹم ہے جیڑھا رگ اندر دی دوا دے بہاؤ دی رفتار تے وقفے کوں کنٹرول کریندا ہے۔ ہک میکینیکل ٹائمر تے ہک فلو ریٹ والو انفیوژن ٹیوب دے اُتے تے تھلے رکھے ویندن، تاں جو طبی عملہ بغیر ذہنی حساب دے گھلوندی رفتار تے وقت سیٹ کر سگے۔ جڈاں خوراک مکمل تھی ویندی ہے، تاں والو ہک فزیالوجیکل سلائن موڈ تے سوئچ تھی ویندا ہے تے انجکشن جاری رہیندا ہے، جیڑھا رُجھے ہوئے دوران غلطیاں دے خطرے کوں گھٹ کریندا ہے۔ سلیکون کوں کوئی بجلی دی لوڑ کائنی تے ایں کریں محدود طبی وسائل والے علاقیاں دی خدمت کر سگدا ہے۔

The Recognition

About the A' Design Award چاندی دا انعام

Silicon Primary Function: انفیوژن ڈوزنگ سسٹم A' Design Award چاندی دا انعام دا جتݨ والا ہے، غیر معمولی حد تئیں معزز پچھاݨ جیڑھی اعلیٰ ترین درجے دے، شاندار تے متاثر کرݨ والے ڈیزائناں کوں ݙتی ویندی ہے۔ چاندی دے جتݨ والے بہوں روشن تے انتہائی تخلیقی کم ہن، جیڑھے اپݨے ڈیزائنراں دی شاندار مہارت، صلاحیت تے ذہانت کوں ظاہر کریندے ہن۔ Silicon Primary Function: انفیوژن ڈوزنگ سسٹم کنوں امید کیتی ویندی ہے جو او ہک شاندار نمائشی کم ہوسی، قابل ذکر حد تئیں پیشہ ورانہ تے گہری جدت والا۔ ایہ ڈیزائن جنہاں A' Design Award چاندی دا انعام جتیا ہے، ہک انتہائی قابل ذکر، سراہی ہوئی ایجاد ہے جیڑھی فائدہ ݙیندی ہے تے فن، سائنس، ڈیزائن تے ٹیکنالوجی دیاں حداں ودھیندی ہے۔ Silicon Primary Function: انفیوژن ڈوزنگ سسٹم ہک ایجھی تخلیق ہے جنہاں تے ڈھیر لوک حسد کریندے ہن، جیڑھی خواہشاں جگیندی ہے، مثبت جذبے آݨیندی ہے تے حیرت تے تعجب دی چنگاری بالیندی ہے۔

Behind the Design

Press Kit

Credits, team members and technical details provided by the designer.

Unique Properties
Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
Dimensions & Packaging
Width 110mm x Depth 57mm x Height 302mm
Tags
Infusion,Dosing,Automatic,Timing,Control
Production Technology
After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
Design Challenge
This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
Research
In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
Inspiration
Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution.
Project Duration
Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
Operation Flow
I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing.
Team Members
Designer:Sheng-Lun Huang
Designer:Chih-Yen Lin
Professor:Kai-Chu Li
Medical team:Ciao-Yi Chen
Medical team:Ya-Ling Chen
Medical team:He-Yen Lin
Image Credits
All Images:Designer Sheng-Lun Huang and Chih-Yen Lin