About CST Platform Funksioni Kryesor: Stapler Rrethor
Teksti i Librit: Platforma CST është një stapler rrethor i projektuar për kirurgjinë digjestive. Staplerët rrethorë bashkojnë indet dhe rikthejnë vazhdimësinë e kanalit ushqimor pas heqjes së një pjese të organit. Struktura mbështetëse e brendshme e mbulesës është hequr për të krijuar një kokë pa pengesa, gjë që redukton deformimin e stapleve të shkaktuar nga efekti i pistonit. Mbulesa tubulare e zmadhuar mundëson heqjen e më shumë indeve në një hap të vetëm. Një kyçje automatike sigurie aktivizohet vetëm kur instrumenti është gati për t'u aktivizuar, dhe një tingull i qartë zileje konfirmon që procesi i aktivizimit është përfunduar.
The Recognition
About the Çmimi i Hekurt A' Design Award
CST Platform Funksioni Kryesor: Stapler Rrethor është fitues i Çmimit të Hekurt A' Design Award, një njohje prestigjioze që u akordohet dizajneve të mira që plotësojnë kërkesat profesionale e industriale që priten nga krijimet e dizajnuara mirë. Fituesit e Hekurt shfaqin aftësi të madhe, specializim të lartë, kuptim ekspert dhe kapacitet krijues të autorëve të tyre. CST Platform Funksioni Kryesor: Stapler Rrethor pritet të jetë një krijim shumë i vlerësuar, i admiruar e i dashur, praktik dhe inovativ. Ky dizajn fitues i Çmimit të Hekurt A' Design Award integron praktikat më të mira të industrisë dhe ka karakteristika teknike të afta, të lidhura me njohuri dhe talent. CST Platform Funksioni Kryesor: Stapler Rrethor respektohet për përpikërinë e tij dhe është dizajnuar për të ofruar përmirësime të cilësisë së jetës që ndihmojnë ta bëjnë botën një vend më të mirë.
Behind the Design
Press Kit
Credits, team members and technical details provided by the designer.
- Unique Properties
- The most important thing that surgeons can focus on their patients and the life-saving procedures. Medical devices can help surgeons achieve their goals.
CST platform is an advanced circular stapler platform. A build-in barrier-free structure helps to solve the problem of malformation which caused by the piston effect. Engineer removed the problem maker—internal supporting structure, increased the head volume, to get flat and even tissue condition. This will ensure the tissue won’t milk out from the head part of circular stapler while it is fired.
Safety lock of a circular stapler plays an important role in the surgery. When the indicator is not fully within the green range while tissue is being compressed, attempting to fire may cause a disaster. After firing, re-squeeze the firing handle will also damage the anastomosis ring. That’s why all other circular stapler set a manual safety lock to avoid problems. Nonetheless, surgeons forget to release or reset the safety lock that still occurs. The designer created the 4th generation automatic safety lock. It is smart, will engage driven members only when the instrument is in the correct firing status. This solves problems fundamentally.
CST platform also provides audible feedback to remind the surgeon that she/he has completed the firing successfully. - Dimensions & Packaging
- Product dimensions differs in different models. General dimension, height: 501mm, width: 186mm, depth: 34.5mm. Weight: 470g. Firing force: nearly 200N
e.g. CST29: the diameter of the stapler housing is 29mm, the volume of tubular casing is 13.2 cubic millimeter, the area of opening windows: 1332 square millimeter - Tags
- Medical device, Surgery, Surgical stapler, Circular stapler, Anastomosis, Barrier-Free, Piston effect, Leverage-Control, Automatic safety lock
- Production Technology
- We care about all aspects of product experience. We hope that during the firing, the surgeon can not only feel but also hear the feedback from the device. A clear and distinctive bell tone can be heard after firing, which reminds surgeon to avoid re-squeeze the firing trigger. It increases the safety level of an operation.
- Design Challenge
- Engineer should be balanced by many factors, such as process, material, cost, etc. Engineering validation brings us the great challenges to remove the support structure of stapler housing, the rigidity of the tubular casing is reduced to cause the yaw of the anvil. Engineers work on design, materials, and processes to resolve this contradiction.
Firstly, improve the design. After removing the support structure, engineers insert a stainless steel sleeve in the anti-expansion tube to reduce the gap between the anvil shaft and the anti-expansion tube, increase the precision and coaxial.
Secondly, search for higher strength and biosafety materials to meet new design demands.
Thirdly, in terms of processing and manufacturing processes, machining accuracy must reach the micron level to meet our design expectations. Nonetheless, higher design standards and assembly accuracy have also brought huge challenges to the product percent of pass and cost. - Research
- To provide excellent products, engineers had analyzed the main technical indicators such as the stress analysis of the core components, staple formation, etc.
While the instrument is being closed, the head part has to bear up to 90kgf force to compress the tissue. During the firing, it needs another 48kgf force to cut through the washer and 50kgf force to ensure proper staple formation. We have reinforced the structure of the stressed components and selected heavy strength materials to bear the huge force.
The yaw of the anvil is a very important index, which directly affects whether the staple leg can be aligned with the forming notch or not. Engineers designed a yaw test scheme: apply 10kgf lateral force to the anvil to measure its yaw. In this test, the actual swing of CST is less than 0.2 mm, which is 60% less than the average value 0.53mm. - Inspiration
- Surgical staples for internal use are medical devices used to deliver compatible staples to internal tissues during surgery. In 1978, the first circular stapler was invented, mainly used in gastrointestinal, gynecological, and thoracic surgery. More than 15 million surgical procedures were done with staplers in 2018 with an increasing rate of 7.2% year by year. For more than 40 years, no breakthrough development of circular staplers’ structure and performance. Problems such as the limited volume of the tubular casing and poor consistency of staple formation have plagued surgeons and manufacturers. In the United States only, annual adverse events due to staples malformation accounted for 32.1% of the overall reports, and almost 1% of patients died accordingly. According to our research,the malformation is caused by the piston effect in the head part of circular stapler. It will challenge us to rethink and redefine what is possible and how we can improve circular staplers to our surgeons and benefit to patients.
- Project Duration
- Nearly eleven years in development, the project began in January 2008 and released in Suzhou, Milano, New York, and Sydney in August 2018.
- Operation Flow
- CST platform is used in digestive surgery. It has the same indication as the conventional circular stapler. The main difference is product performance and user experience.
The most clinical benefit of CST platform is that with barrier-free, the occurrence of surgical leakage caused by staple malformation, which is the severe postoperative complication, will decrease remarkably.
Thanks to the enlarged volume of the tubular casing, now with one CST stapler,the surgeon is able to resect the amount of tissue in which conventionally needs two. This helps to reduce the cost of medical treatment for patients.
With the adoption of the 4th generation automatic safety lock, it changes the complicated operation of instruments into simple, shortens the learning curve of surgeons, let them concentrate on the surgery itself. - Patents
- Patent No.:
PCT/CN2018/121973, PCT/CN2018/120698, PCT/CN2018/120697, PCT/CN2018/118111, PCT/CN2018/120699, PCT/CN2018/122049, PCT/CN2018/120122
CN201711434954.3, CN201711431490.0, CN201711434138.2, CN201711435672.5, CN201711435644.3, CN201711434086.9, CN201711451948.9, CN201711472884.0, CN201711473924.3, CN201711473925.8, CN201711478115.1, CN201711472892.5, CN201711473891.2 - Team Members
- Designer:Lane Foo,
Engineer:Terry Lin, Alex Guo, Chris Chen, Jackel Ding, Tom Liu