Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu by New Design Biotechnology Co., Ltd is a highly esteemed winner of the very prestigious 2023 A' Design Award Hao in Hoʻolālā Nani, Mālama Pilikino a me Huahana Hoʻonani Competition Category.
HaoHuahana Hoʻonani· 2023
Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu
by New Design Biotechnology Co., Ltd
Client: GuangZhou New-Design Biotechnology Co.,Ltd
A' Design Award Hao Winner in Huahana Hoʻonani Category
Verified Award Winner
Verify Award Status for #145981The Design
About Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu
Kikokikona Puke: ʻO Rhinitis Aid he mea kāhea kukui ʻulaʻula lawe wāwae no ka poʻe loaʻa i ka maʻi rhinitis allergic. Hoʻopili ʻia ka ʻāpana nui uila ʻole ma ka ihu a ʻike ʻia ka kaumaha he 14 kalama, no laila ʻaʻohe pono i nā uea hoʻopili. ʻElua mea hoʻokukui LED ʻāpana wikiwiki haiki me ka lōʻihi hawewe waena he 630 nanometers e alakaʻi ana i ke kukui ʻulaʻula i loko o ka lua ihu. He ʻelima minuke ka lōʻihi o kēlā me kēia hoʻāʻo lapaʻau a laila pau wale nō ia ma o kāna ponoʻī. Hoʻohana ka pahu hoʻouka mana i ke kukui ultraviolet e hoʻomaʻemaʻe i ka mea ma waena o ka hoʻohana ʻana. ʻO ke kino liʻiliʻi e hiki ai ke lawe ʻia a hoʻohana ʻia ka mea i nā manawa a pau.
The Recognition
About the A' Design Award Hao
Ua lanakila ka hoʻolālā Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu i ka A' Design Award Hao, he ʻike hoʻohanohano i hāʻawi ʻia i nā hoʻolālā maikaʻi e hoʻokō ana i nā koi ʻoihana a ʻoihana hana i manaʻo ʻia mai nā mea hoʻokumu i hana maikaʻi ʻia. Hōʻike nā lanakila Hao i ka mākau nui, ka loea kiʻekiʻe, ka ʻike akamai a me ka hiki hana noʻeau o ka poʻe i hana iā lākou. Manaʻo ʻia ʻo ka hoʻolālā Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu he mea hoʻokumu i mahalo nui ʻia, hoʻohiwahiwa ʻia a aloha ʻia e pono a hou. ʻO kēia hoʻolālā i lanakila i ka A' Design Award Hao e hoʻohui ana i nā hana maikaʻi loa o ka ʻoihana a loaʻa nā ʻano ʻenehana mākaukau i hui pū ʻia me ka ʻike hana a me ka makakoho. Mahalo ʻia ka hoʻolālā Rhinitis Aid Hana Nui: Mea Kāhea Kukui no ka Ihu no kona nānā pono a ua hoʻolālā ʻia e hāʻawi i nā hoʻomaikaʻi ola e kōkua ai i ka hana ʻana i ka honua i wahi maikaʻi aku.
Behind the Design
Press Kit
Credits, team members and technical details provided by the designer.
- Unique Properties
- A portable, comfortable and sterile product for patients with rhinitis.Wearing comfort: pinch-nose structure, removing connecting wires, the mainframe only weighs 14g.Aseptic therapy: The charging chamber has ultraviolet sterilization function Small enough to carry around.Portable: Small enough to carry around and use at any time.Class II medical device certification, clinically tested and valid, charging chamber disinfection efficiency up to 99.99%.
- Dimensions & Packaging
- 82mm x 58mm x 38mm, the product is small and easy to carry. The rhinitis phototherapy instrument is designed for reducing the symptoms of allergic rhinitis such as nasal congestion, running nose and sneezing. It is suitable for use by anyone without any side effects.
- Tags
- Rhinitis Remission, Rhinitis Therapy Apparatus, Red Phototherapy, Aseptic Therapy, Portable
- Production Technology
- The rhinitis phototherapy instrument is focused on the nasal cavity for phototherapy through the red light generated by two narrow-band light emitting diodes with a central wavelength of 630 nm. Red light stimulates the activity of antioxidant (SOD and cataiase), inhibits active oxides that induce sensitive symptoms, stabilizes mast cells, thereby reducing the release of histamines and the production of protein antibodies.
- Design Challenge
- Pinch-nose structure, removing connecting wires.Small enough to carry around and use at any time.
- Research
- Low-intensity phototherapy has been used in medical therapy for decades, and phototherapy is achieved through bioregulation. Low intensity cold light source will not cause surface tissue damage and no residues to organism when applied as energy. The light source of the rhinitis phototherapy instrument emits special red light that protects the nasal mucosa against allergy factors.
- Inspiration
- The existing red rhinitis instrument is connected to the host through a long wire and the product is large in size, which greatly affects the comfort of daily use and wear. The nose is one of the most susceptible parts of bacterial infection. It provide patients with the ability to kill virus and sterile function to eliminate secondary infection problems.
- Project Duration
- The project will be completed in April 2022 in Guangzhou for half a year.
- Operation Flow
- Press the power key and the auxiliary therapy beam emits. Press the protrusions on both sides to adjust the opening distance of the nasal plug tube. Ensure that two microwave light sources enter the nasal cavity for 1-1.5 cm. The micro-light will automatically turn off 5 minutes after the treatment starts, and the LED light of the treatment head flashes when the battery is low. When the host power is low, the charging contact of the host can be lowered into the charging box for charging.
- Team Members
- Shaowei Zhang
Sile Zou
Hongtai Lin
Weijie Shen
Weijian Xie
Jialiang Li
Shengyan Liang
Jinxing Li - Image Credits
- GuangZhou New-Design Biotechnology Co.,Ltd
Sponsored
Explore Beyond Designers.org
Discover products, services and opportunities from our advertising partners.
More to Explore
Related Designs
Explore more award-winning designs from the same category, selected by merit.