Skip to content
Bracesys Aanpasbare Rigide Orthese by Osteoid Design Team
Bracesys Aanpasbare Rigide Orthese by Osteoid Design Team
Bracesys Aanpasbare Rigide Orthese by Osteoid Design Team
Bracesys Aanpasbare Rigide Orthese by Osteoid Design Team
Bracesys Aanpasbare Rigide Orthese by Osteoid Design Team

Goud Medisch Product · 2025

Bracesys Aanpasbare Rigide Orthese

by Osteoid Design Team

  • A' Design Award in Goud 2025 in Medisch Product
  • CLIENT: Osteoid Saglik Teknolojilari AS
  • Estimated Number of Design Views: 44,461
  • Verification code 406CD20E30 · Verify this award
Email this page

Colors

About Bracesys Aanpasbare Rigide Orthese

Bracesys biedt een modulaire orthopedische orthese die zich gedurende het genezingsproces aanpast aan het lichaam van de patiënt. Ontworpen voor pasvorm en aanpassing ter plaatse, vervangt het traditioneel gipsverband door een praktischer, hygiënischer en comfortabeler alternatief. De herbruikbare structuur helpt medisch afval te verminderen, terwijl gestandaardiseerde maatvoering het toegankelijker maakt voor diverse patiëntengroepen. Bracesys brengt flexibiliteit, duurzaamheid en gebruiksgericht denken naar orthopedische zorg.

About the A' Design Award in Goud

Bracesys Aanpasbare Rigide Orthese is winnaar van de A' Design Award in Goud, een immens prestigieuze erkenning die wordt toegekend aan eersteklas, schitterende en uitmuntende ontwerpen. Winnaars in Goud zijn uiterst innovatieve, zeer visionaire en glamoureus verblindende creaties die het genie, de wijsheid en de bekwaamheid van hun ontwerpers weerspiegelen. Bracesys Aanpasbare Rigide Orthese wordt verwacht een zeer geprezen, trendzettende en monumentale uitvinding te zijn die ongekende waarde levert. Dit ontwerp dat de A' Design Award in Goud heeft gewonnen, is een spectaculair, gerespecteerd project dat enorm baat en de grenzen van kunst, wetenschap, ontwerp en technologie verlegt. Bracesys Aanpasbare Rigide Orthese wekt intense gevoelens van verlangen, roept passie op, moedigt creativiteit aan en fascineert ons.

Press Kit

Unique Properties
Bracesys is a patented, rigid orthopedic brace framework featuring segmented units connected by adjustable articulating connectors and tension dials. Clinicians independently fine-tune each segment, closely matching patient anatomy, providing secure immobilization, and accommodating anatomical changes during recovery. It simplifies clinical procedures, enhances daily patient comfort, and promotes sustainability through recyclable materials and reuse within controlled clinical protocols.
Dimensions & Packaging
Bracesys includes specific models like distal radius, colles, shaft fractures in four standardized sizes, covering anatomical variations from the 5th to 95th percentile. A mid-sized Colles fracture brace typically weighs 150 grams, measuring approximately 190 x 90 x 115 mm assembled, and folds flat into an A4 sized envelope for convenient transport. Clinicians use small, screwdriver-sized tools for rapid fitting, precise customization, and incremental adjustments during patient recovery.
Tags
Rigid Orthopedic Brace, Customizable Orthosis, Sustainable Healthcare, Modular Framework, 3D Orthotics, Medical Cast
Production Technology
Bracesys was developed within a CAD environment through iterative prototyping and 3D-printing SLS/MJF using medical-grade Nylon 12, reinforced by CNC-machined aluminum, stainless steel, and Kevlar cables for robust structural performance. Anatomical accuracy was ensured by analyzing hundreds of anonymized patient CT scans via AI-driven segmentation, implicit skinning algorithms, and statistical shape analysis to precisely define patient-contact surfaces and ensure anatomical compatibility.
Design Challenge
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside with running the business sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Research
This applied research addresses the need for anatomically accurate, rapidly customizable orthopedic braces. Over 600 anonymized patient hand CT scans were analyzed through AI driven segmentation ,Pix2Pix GAN, implicit skinning algorithms for standardized anatomic alignment, and statistical modeling, Principal Component Analysis, for sizing. Mechanical tests validated structural integrity, while clinical use provided feedback for sizing, comfort and fitting procedures influencing the design.
Inspiration
Current orthopedic solutions present trade-offs: off-the-shelf braces rarely fit accurately, while custom 3D-printed alternatives involve lengthy, complex processes that limit their clinical use. Inspired by the precision engineering of timepiece mechanics and sailing rigging systems, Bracesys emerged from a quest to develop a rapid, expert-driven approach that precisely accommodates diverse and evolving patient anatomies, prioritizing comfort, speed, and sustainability.
Project Duration
Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside another demands sustained strategic prioritization careful resource allocation and continuous commitment to innovation
Operation Flow
Bracesys is placed around the limb in a loosely connected circular form, with pre-configured structural segments linked by articulated connectors and loose internal cables, naturally conforming to clinically prescribed anatomical alignment. Clinicians use tools to adjust connector length and incrementally tighten integrated tension dials, mechanically locking the brace into a rigid, supportive configuration. Spring-loaded quick-release pins enable easy loosening for adjustments or brace removal.
Patents
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted patents / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending patent applicants / Applicant Osteoid Saglik Teknolojileri AS
Image Credits
US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted / Patent holder Osteoid Saglik Teknolojileri AS

US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending / Patent applicant Osteoid Saglik Teknolojileri AS

Image #1 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #2 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #3 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #4 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #5 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Video #1 / Cameraman / Murat Sariaslan / Santral Fotoğraf, 2025.

Related Designs

View All

Good Design Deserves Great Recognition

Nominate Your Work for the A' Design Award.

Nominate