Khauta Sehlahiswa sa Bongaka · 2025
Bracesys Sesebelisoa sa Tshehetso sa Masapo se Tiileng se ka Lokisiwang
- Moputso oa Khauta oa A' Design Award 2025 in Sehlahiswa sa Bongaka
- CLIENT: Osteoid Saglik Teknolojilari AS
- Estimated Number of Design Views: 44,461
- Verification code 406CD20E30 · Verify this award
Colors
About Bracesys Sesebelisoa sa Tshehetso sa Masapo se Tiileng se ka Lokisiwang
Bracesys e fana ka sesebelisoa sa orthopedie se nang le dikarolo tse fapaneng se ikamahanyetsang mmele wa mokudi nakong ya tshebetso ya ho fola. E hlophisitswe bakeng sa ho lokiswa sebakeng le ho fetolwa habonolo, e nkela sebaka mokgwa wa setso wa ho roala ka pulaseta ka kgetho e sebetsang hantle, e hloekileng, hape e phutholang. Sebopeho sa yona se ka sebeliswang hape se thusa ho fokotsa matlakala a bongaka, ha boholo bo lokisehileng bo etsa hore e fumanehe habonolo dihlooheng tse fapaneng tsa bakudi. Bracesys e tlisa ho feto-fetoha, tšoarello, le mokhoa wa ho nahana o shebahelang basebelisi tlhokomeleng ya orthopedie.
About the Moputso oa Khauta oa A' Design Award
Bracesys Sesebelisoa sa Tshehetso sa Masapo se Tiileng se ka Lokisiwang ke mohapi oa Moputso oa Khauta oa A' Design Award, kananelo e hlomphehang haholo e fuoang meralo ea maemo a pele, e ntle ka ho makatsa le e ikhethang. Bahapi ba Khauta ke lintho tse hlahisitsoeng tse nang le mehopolo e mecha haholo, tse shebileng pele le tse khanyang ka ho foufatsa, tse bontšang botsebi, bohlale le bokhoni ba baqapi ba tsona. Bracesys Sesebelisoa sa Tshehetso sa Masapo se Tiileng se ka Lokisiwang e lebelletsoe ho ba mohopolo o babatsoang haholo, o thehang mekhoa e mecha le o moholo, o tlisang boleng bo sa kang ba bonoa. Moralo ona o hapileng Moputso oa Khauta oa A' Design Award ke mosebetsi o tsosang maikutlo, o hlomphehang, o tlisang molemo o moholo le o sutumelletsang meeli ea bonono, mahlale, moralo le theknoloji. Bracesys Sesebelisoa sa Tshehetso sa Masapo se Tiileng se ka Lokisiwang e hlahisa maikutlo a matla a takatso, e tsosa tjantjello, e khothalletsa boqapi mme e re khahlisa.
Press Kit
- Unique Properties
- Bracesys is a patented, rigid orthopedic brace framework featuring segmented units connected by adjustable articulating connectors and tension dials. Clinicians independently fine-tune each segment, closely matching patient anatomy, providing secure immobilization, and accommodating anatomical changes during recovery. It simplifies clinical procedures, enhances daily patient comfort, and promotes sustainability through recyclable materials and reuse within controlled clinical protocols.
- Dimensions & Packaging
- Bracesys includes specific models like distal radius, colles, shaft fractures in four standardized sizes, covering anatomical variations from the 5th to 95th percentile. A mid-sized Colles fracture brace typically weighs 150 grams, measuring approximately 190 x 90 x 115 mm assembled, and folds flat into an A4 sized envelope for convenient transport. Clinicians use small, screwdriver-sized tools for rapid fitting, precise customization, and incremental adjustments during patient recovery.
- Tags
- Rigid Orthopedic Brace, Customizable Orthosis, Sustainable Healthcare, Modular Framework, 3D Orthotics, Medical Cast
- Production Technology
- Bracesys was developed within a CAD environment through iterative prototyping and 3D-printing SLS/MJF using medical-grade Nylon 12, reinforced by CNC-machined aluminum, stainless steel, and Kevlar cables for robust structural performance. Anatomical accuracy was ensured by analyzing hundreds of anonymized patient CT scans via AI-driven segmentation, implicit skinning algorithms, and statistical shape analysis to precisely define patient-contact surfaces and ensure anatomical compatibility.
- Design Challenge
- Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside with running the business sustained strategic prioritization careful resource allocation and continuous commitment to innovation
- Research
- This applied research addresses the need for anatomically accurate, rapidly customizable orthopedic braces. Over 600 anonymized patient hand CT scans were analyzed through AI driven segmentation ,Pix2Pix GAN, implicit skinning algorithms for standardized anatomic alignment, and statistical modeling, Principal Component Analysis, for sizing. Mechanical tests validated structural integrity, while clinical use provided feedback for sizing, comfort and fitting procedures influencing the design.
- Inspiration
- Current orthopedic solutions present trade-offs: off-the-shelf braces rarely fit accurately, while custom 3D-printed alternatives involve lengthy, complex processes that limit their clinical use. Inspired by the precision engineering of timepiece mechanics and sailing rigging systems, Bracesys emerged from a quest to develop a rapid, expert-driven approach that precisely accommodates diverse and evolving patient anatomies, prioritizing comfort, speed, and sustainability.
- Project Duration
- Key challenges were obtaining and analyzing extensive anatomical data involving over six hundred anonymized CT scans as well as iterative mechanical refinement through prototyping while ensuring precise geometry Regulatory compliance was straightforward for new brace models but complicated for controlled clinical reuse Managing this rigorous development alongside another demands sustained strategic prioritization careful resource allocation and continuous commitment to innovation
- Operation Flow
- Bracesys is placed around the limb in a loosely connected circular form, with pre-configured structural segments linked by articulated connectors and loose internal cables, naturally conforming to clinically prescribed anatomical alignment. Clinicians use tools to adjust connector length and incrementally tighten integrated tension dials, mechanically locking the brace into a rigid, supportive configuration. Spring-loaded quick-release pins enable easy loosening for adjustments or brace removal.
- Patents
- US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted patents / Patent holder Osteoid Saglik Teknolojileri AS
US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending patent applicants / Applicant Osteoid Saglik Teknolojileri AS - Image Credits
- US12090080B2, EP3285647B1, CN107771069B, JP6756735B2, US10932940B2 Granted / Patent holder Osteoid Saglik Teknolojileri AS
US20240009014A1, EP4312904A1, JP2024511129A, CN117396161A Pending / Patent applicant Osteoid Saglik Teknolojileri AS
Image #1 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #2 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #3 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #4 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Image #5 / Photographer / Murat Sariaslan / Santral Fotoğraf, 2025.
Video #1 / Cameraman / Murat Sariaslan / Santral Fotoğraf, 2025.