ʻO Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau na Sheng-Lun Huang and Chih-Yen Lin he mea lanakila hanohano loa o ka 2021 A' Design Award Kala ma ka Māhele Hoʻokūkū Hoʻolālā Manaʻo a me Hoʻolālā Kuhi.
KalaManaʻo· 2021
Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau
na Sheng-Lun Huang and Chih-Yen Lin
Mea Kūʻai: Design Lions
Mea Lanakila A' Design Award Kala ma ka Māhele Manaʻo
Mea Lanakila i Hōʻoia ʻIa
Hōʻoia i ke Kūlana Makana no #121915Ka Hoʻolālā
E Pili Ana iā Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau
Book Text: ʻO Silicon he ʻōnaehana hoʻoili lāʻau ʻakomi hapa e hoʻomalu ana i ka wikiwiki o ke kahe a me ka lōʻihi o ka lāʻau i hoʻokomo ʻia i loko o ke aʻa. Hoʻokau ʻia kahi mīkini helu manawa a me kahi hāmama hoʻomalu wikiwiki kahe ma luna a ma lalo o ke aʻa hoʻoili, no laila hiki i nā limahana lapaʻau ke hoʻonohonoho i ka wikiwiki o ke kulu a me ka manawa e pono ai me ka helu ʻana i loko o ka noʻonoʻo ʻole. Ke pau ka nui o ka lāʻau, huli ka hāmama i kahi ʻano wai paʻakai kino a hoʻomau ka hoʻokomo ʻana, kahi e hōʻemi ai i ka pilikia o nā hewa i nā manawa hana nui. ʻAʻole pono ʻo Silicon i ka uila a no laila hiki iā ia ke lawelawe i nā wahi me nā kumuwaiwai lapaʻau palena ʻia.
Ka Hoʻomaikai
E Pili Ana i ka A' Design Award Kala
Ua lanakila ka hoʻolālā Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau i ka A' Design Award Kala, he ʻike hoʻohanohano nui loa i hāʻawi ʻia i nā hoʻolālā kiʻekiʻe loa, nani a kupaianaha. He mau hana ʻālohilohi loa a hana noʻeau nui nā lanakila Kala e hōʻike ana i ka loea, ka makakoho a me ka ʻoi aku o ka noʻonoʻo o kā lākou poʻe hoʻolālā. Manaʻo ʻia ʻo ka hoʻolālā Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau he hana kupaianaha, kūlana ʻoi aku, ʻoihana kiʻekiʻe a hou loa. ʻO kēia hoʻolālā i lanakila i ka A' Design Award Kala he mea hoʻokumu kūpono loa, mahalo ʻia e hāʻawi i ka pōmaikaʻi a hoʻoneʻe i nā palena o ka hana noʻeau, ka ʻepekema, ka hoʻolālā a me ka ʻenehana. He mea i ʻeleu ʻia e nā mea he nui ka hoʻolālā Silicon Primary Function: ʻŌnaehana Hoʻoili Lāʻau e hoʻāla i ka makemake, lawe mai i nā manaʻo maikaʻi a hoʻāla i ka kamahaʻo a me ka mahalo.
Ma Hope o ka Hoʻolālā
ʻEke Nūhou
Nā hōʻoia, nā lālā hui a me nā kikoʻī ʻenehana i hāʻawi ʻia e ka mea hoʻolālā.
- Nā ʻAno Kūʻokoʻa
- Silicon is a semi automatic precise infusion solution dosing system, by simple mechanical timer and flow rate valve to improve medical negligence by staff control of flow rate and time of drip medicine, It does not require electricity to replace expensive electronic automatic detection devices, helping resources deprived areas.
- Nā Ana a me ka Hoʻopili
- Width 110mm x Depth 57mm x Height 302mm
- Nā Lepili
- Infusion,Dosing,Automatic,Timing,Control
- ʻEnehana Hana
- After completing the dosing, the internal structure of the upper drug timer and the lower timing flow rate valve will drive the aperture flow rate valve to switch to the physiological saline mode, open the physiological saline hole, and continue to inject into the patient body to prevent the medical staff from being busy time negligence caused accidents.
- Pilikia Hoʻolālā
- This is the third generation design. Each generation of design is more in line with the process sequence, ergonomics, and long term cooperation with the medical team for testing. In order to solve the timing problem, we challenged different structures and methods of calculating the flow rate, and needed to confirm that the drug was completely injected without harming the patient, so this is a difficult challenge.
- Noiʻi
- In fact, we interviewed nurses and trainee nurses who are used every day, and learned about the existing intravenous infusion procedures. Therefore, the design and research of the drug timer structure and the timing flow rate valve structure improve the accuracy of intravenous drug injection and make the work of medical staff more convenient and accurate.
- Hoʻoulu Manaʻo
- Through interviews with medical staff, it was found that some medicines need to be injected for about 30 to 60 minutes and the medical staff must mentally calculate the drip flow rate and monitor the drip status back and forth. Not only does it make the medical staff feel stressed, but in the busy peak hours, it is easy for them to forget about patients medical treatment, causing accidents.
Each year, the health care industry creates billions of pounds of waste on average, with the prevalence of disposable medical materials causing a rapid depletion of health care resources and a lot of environmental pollution. - Ka Lōʻihi o ka Papahana
- Silicon development has made great efforts together with medical staff. In a tight year, we realized that this is a daunting challenge and helped medical staff to reduce their hardship.
- Kaʻina Hana
- I.Close the water inlet hole.
II.Put the medicine bottle in place.
III.Adjust the flow rate valve aperture.
IV.Adjust the flow rate valve timer.
V.Adjust the medicament timer.
VI.Attach a special identification label.
Dosing method:
I.Silicone puncture dosing
II.Automatic dosing stand dosing:By pressing the button of the dosing stand, the control structure can fix the medicine bottle in place. The dosing stand contains a needle that can automatically puncture the medicine bottle to achieve automatic dosing. - Nā Lālā Hui
- Designer:Sheng-Lun Huang
Designer:Chih-Yen Lin
Professor:Kai-Chu Li
Medical team:Ciao-Yi Chen
Medical team:Ya-Ling Chen
Medical team:He-Yen Lin - Nā Kuleana Kiʻi
- All Images:Designer Sheng-Lun Huang and Chih-Yen Lin
Kākoʻo ʻIa
ʻImi ma ʻō aku o Designers.org
E ʻimi i nā huahana, nā lawelawe a me nā manawa mai kā mākou mau hoa hoʻolaha.
Hou Aku e ʻImi Ai
Nā Hoʻolālā Pili
E ʻimi i nā hoʻolālā lanakila hou mai ka māhele like, i koho ʻia ma ka waiwai.